Applicability Analysis of CO Measuring Instrument in Refuge Chamber
-
Graphical Abstract
-
Abstract
Electrochemical sensing element is wildly used in mine CO measuring instrument, and its reaction mechanism exhibits cross-reactivity in the refuge chamber, there is a great measurement error in complex gas circumstances. This paper analyzes the gas composition in refuge chamber with electrochemical reaction, presents the characteristic of data differences and provides some methods of resistance cross interference.
-
-