Grouting Control Technology for Spontaneous Combustion Area in the Deep of Waste Dump of Daliuta Coal Mine
-
Graphical Abstract
-
Abstract
In this paper,by using ground drilling grouting to isolate deep fire area in the waste dump, cutting off the CO diffusion channel and covering sand to cut from the fire area oxygen conditions, the threat of deep spontaneous combustion area in the waste dump to mine safety production is seffectively relieved.
-
-