LIU Jingwei, ZHANG Xiaobo, SUN Zhifei, HU Yun. Design of Constant / Closure Output Protection Circuit for Coal Mine Sensor[J]. Safety in Coal Mines, 2016, 47(1): 97-99.
    Citation: LIU Jingwei, ZHANG Xiaobo, SUN Zhifei, HU Yun. Design of Constant / Closure Output Protection Circuit for Coal Mine Sensor[J]. Safety in Coal Mines, 2016, 47(1): 97-99.

    Design of Constant / Closure Output Protection Circuit for Coal Mine Sensor

    • In view of mine inflammable and special explosive environment and sensor equipment static and group pulse EMC interference problem, a constant/closure output protection circuit has soft start, constant / closure output and self-recovery function. We detail the protection circuit design, soft start, constant current output, and the output of closure and self-recovery circuit design, compared by experiments and existing sensor equipment, power supply module; we design protection circuit with existing intrinsically safe power supply protective circuit. The protection circuit has soft start protection, anti-jamming and anti-load ability of the impact; overcurrent fault is lifted to automatic recovery, without the need to add additional recovery circuit. The circuit adopts the basic device with fast response time and good stability.