Abstract
Through reasons analysis of water bursting from hidden subsided column at 10111 working face in Huangcun Branch of Fenjin Coal Mine, the study implemented a targeted water damage prevention measures, including plugging water bursting point, three-dimensional seismic exploration, ground drilling, underground geophysical exploration, partial grouting which provided a scientific basis for prevention and control of mine water disaster.
-
-