Gas Extraction Drilling Flow Attenuation Laws and Reasons Analysis in Fuyan Coal Mine
-
Graphical Abstract
-
Abstract
In order to analyze gas extraction drilling flow attenuation laws and reasons of Fuyan Coal Mine, the paper studies this by adopting the method of field test combined with theoretical analysis. Based on regression analysis of field test data, the paper obtained that gas extraction drilling hole flow attenuation law is in line with the logarithmic formula qt=-39.989ln(t)+257.94 ,the correlation coefficient R2=0.941 5.It was thought that coal seam gas pressure reducing and drilling leakage are the mine reasons of pure flow attenuation.
-
-