矿用呼吸器面罩泄漏率测试装置
Leakage Rate Testing Device for Mine Respirator Mask
-
摘要: 在综合考虑产品及使用者特点的基础上,针对矿用呼吸器用面罩研究设计了一套泄漏率测试装置。装置中设计了10组能够覆盖中国成年男子不同脸型特点的仿人头模,可以在无真人参与实验的条件下,实现面罩泄漏率的准确、稳定检测。经试验验证,该装置的油雾浓度控制标准偏差为3.02 mg/cm3,全面罩和半面罩的泄漏率测试重复性误差分别为0.6%和1.2%。Abstract: Considering the characteristics of products and users, a set of leakage rate testing device is designed for mine respirator masks. In the device, 10 sets of imitation models of human heads are designed which can cover the different facial features of Chinese adult men. The accurate and stable detection of the leakage rate of masks can be realized without the participation of real people. The experimental results show that the standard deviation of oil mist concentration control is 3.02 mg/cm3, and the repeatability errors of leakage rate test for full masks and half masks are 0.6% and 1.2% respectively.
-
-
[1] 贾其文.正压呼吸器浅析[J].煤矿安全,2001(1):22-24. [2] GB 2890—2009 呼吸防护 自吸过滤式防毒面具[S]. [3] 陈吉,金士良,洪跃.个人防护口罩泄漏率测试装置设计[J].工业计量,2009(6):6-8. [4] 叶翔宇,杨志清,王倩,等.PM2.5日用防护口罩检测技术探讨[J].中国纤检,2016(3):94-101. [5] 吴楠,刘才容,王康建,等.防尘口罩密合性检测方法及相关标准[J].轻工科技,2015(1):98-99. [6] 杨小兵,房鹤,袁晓华,等.防毒面具新型多功能捡漏测试评价系统[J].中国个体防护装备,2013(3):40-43. [7] GB/T 5703—2010 用于技术设计的人体测量基础项目[S]. [8] GB/T 2428—1998 成年人头面部尺寸[S]. [9] 刘孟德.超声波油雾发生器的机理及实验[J].石油和化工设备,2012(1):22-24. [10] 顾乃谷,陆振林,王莉华,等.防放射性微粒呼吸器泄漏率测试装置[J].辐射防护,1990(5):382-386.