Abstract:
To study the numerical relationship between
V1 value of gas desorption velocity and
W value of gas content in coal seam in the first minute, three kinds of non-structural coal, anthracite, lean coal and long-flame coal, were used to test the desorption rules under the adsorption equilibrium pressure of 3.0 MPa, 1.7 MPa and 0.5 MPa. Through the linear fitting processing, the linear correlation coefficient R
2 of
V1 and
W is between 0.915 7 and 0.999 4, the results showed that the gas content
W could be determined rapidly by
V1. Field verification shows that the absolute error of gas content measurement is -0.63 to 1.25, and the relative error is 1.23% to 8.81%, which meets the engineering requirements.