地面瓦斯抽采泵站防雷设计
Design of Lightening Protection of Surface Gas Drainage Pump Station
-
摘要: 介绍了瓦斯抽采泵站防雷设计应遵守的规程、规范及标准;确定了瓦斯抽采泵站放散管、瓦斯泵房的防雷类别;确立了瓦斯泵站防雷应保护范围,并对瓦斯抽采泵站防雷采用不同型式接闪器的可行性作了分析,对瓦斯泵站防雷设计有一定借鉴作用。Abstract: The paper introduces the regulation and criterion of lightening protection of gas drainage pump station, determines the category of lightening protection of release pipe of gas drainage pump station and the protection scope of lightening protection of gas pump station and analyzes the viability of different types of lighting arresters adopted on gas drainage pump station, the design would has certain reference value to the lightning protection design of gas pump station.
-
-
[1] GB 50471—2008 煤矿瓦斯抽采工程设计规范[S]. [2] GB 50057—2010 建筑物防雷设计规范[S]. [3] GB 50215—1994煤炭工业矿井设计规范[S]. [4] GB 50215—2005煤炭工业矿井设计规范[S]. [5] GB 50215—2015煤炭工业矿井设计规范[S]. [6] 胡天禄,郁继裳,钱粤民,等.煤矿电工手册[K].北京:煤炭工业出版社,1996:1-31. [7] AQ 1077—2009 煤矿瓦斯往复式内燃机发电站电安全要求[S]. [8] 国家安全生产监督管理局,国家煤矿安全监察局.煤矿安全规程[M].北京:煤炭工业出版社,2016:371. [9] 陈一兵.煤矿地面瓦斯抽采泵站防雷接地设计[J].煤炭工程,2014,46(5):30-32. [10] 齐晨曦.煤矿瓦斯抽放站防雷设计[J].中国高新技术企业,2016,352(1):152-153