Abstract:
through the analysis of H
2S emission in B
1+2 coal seam of Jiangou Mine east wing, the position of H
2S source is determined, which is divided into upper, middle and lower three parts according to the spatial relationship. Different H
2S gas treatment program are designed according to their different source locations, that is negative pressure drainage in upper region, chemical liquid injection and negative pressure drainage in central region and the chemical liquid injection method using in lower region, and these three parts simultaneously treat H
2S gas. Through on-site monitoring, after using H
2S treatment program in chemical muetralization and physical negative pressure drainage method, H
2S gas concentration in return air downs to a safe level, which fully meets the needs of mine safety.